◾Control for main steering gear should be provided from both navigation bridge and steering compartment.
◾In case of chemical tankers and gas carriers two independent hydraulic tele-motors shall be fitted.
◾Auxiliary steering gear shall be operated independently from the wheel house.
◾There should be two independent power supply for the control circuits, one from main switch board and one from emergency switch board.
◾If no emergency generator is there, then two independent connections to be fed to the controller circuits from port and starboard side of the main switch board, so that in case of fire, one can be isolated.
◾In case of failure of main steering gear, second one should start within 45 seconds.
◾Audio and visual alarms to be provided in wheel house for failure of power to the steering gear and control system.
◾Only short circuit protection to be provided on main supply and control system, by means of fuses.
◾There should not be any overload trips, only overload alarms to be provided.
◾Rudder angle indicator to be fitted in wheel house, bridge wings and steering compartment.
◾Ensure dedicated communication system in place, between wheel house and wheel house.
◾Gyro repeater to be fitted in steering gear room so that ship can be steered on desired course from steering room.
◾On wheel house control of steering gear, it should be in position to operate under manual mode (Follow up and Non-Follow up) and auto pilot mode. Change over switch to be provided in wheel house so that in case of emergency operator can change over control to steering room if necessary.

Comments

Popular posts from this blog

External questions by Katyal

         EXTERNAL QUESTIONS SHARED BY KARANAN External: Mr. Katyal Questions asked 1. Tanker Safeties 2. Inert Gas Generator Alarms 3. Portable equipments associated with IG 4. Speed Droop 5. Harmonics 6. What Safeties u observe while changing light in pump room 7. What makes batteries to connect ESB when emg. Gen fails 8. 2 gen are running and current is fluctuating, what is the probable cause 9. Given a ckt diagram consisting of 5 pages of aux engine ckt. Asked one gen not starting. What all checks u do and reasons for not starting 10. In cascade tank there is a sensor apart lever sensor. What it does n how it works 11. What all Safeties u observe while doing maintenance on aux engine Result: Passed. How temp sensor tripping the cop Boiler air servo drive process and signal Epirb What is mmsi How decide life raft capacity What r the thing inside the life raft . How magnetic amplifier works and where it is used . Name-Vijay Pal ...